106 resultados para plasma proteomes

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Synovial fluid is a potential source of novel biomarkers for many arthritic disorders involving joint inflammation, including juvenile idiopathic arthritis. We first compared the distinctive protein ‘fingerprints’ of local inflammation in synovial fluid with systemic profiles within matched plasma samples. The synovial fluid proteome at the time of joint inflammation was then evaluated across clinical subgroups to identify early disease associated proteins. We measured the synovial fluid and plasma proteomes using the two-dimensional fluorescence difference gel electrophoresis approach. Image analysis software was used to highlight the expression levels of joint and subgroup associated proteins across the study cohort (n = 32). A defined subset of 30 proteins had statistically significant differences (p < 0.05) between sample types such that synovial fluid could be differentiated from plasma. Furthermore distinctive synovial proteome expression patterns segregate patient subgroups. Protein expression patterns localized in the chronically inflamed joint therefore have the potential to identify patients more likely to suffer disease which will spread from a single joint to multiple joints. The proteins identified could act as criteria to prevent disease extension by more aggressive therapeutic intervention directed at an earlier stage than is currently possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes the development of the first ion pair solid phase extraction technique (IPSPE), which has been applied to the extraction of metformin from plasma samples. In addition an ion pair chromatographic method was developed for the specific HPLC determination of metformin. Several extraction and HPLC methods have been described previously for metformin, however, most of them did not solve the problems associated with the high polarity of this drug. Drug recovery in the developed method was found to be more than 98%. The limit of detection and limit of quantification was 3 and 5 ng/ml, respectively. The intraday and interday precision (measured by coefficient of variation, CV%) was always less than 9%. The accuracy (measured by relative error, R.E.%) was always less than 6.9%. Stability analysis showed that metformin is stable for at least 3 months when stored at -70degreesC. The method has been applied to 150 patient samples as part of a medication adherence study. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Vitamin B2 exists in blood as riboflavin and its cofactors, flavin mononucleotide (FMN) and FAD. The erythrocyte glutathione reductase activation coefficient (EGRAC) has traditionally been used to assess vitamin B2 status in humans. We investigated the relationships of EGRAC and plasma and erythrocyte concentrations of riboflavin, FMN, and FAD in elderly volunteers and their responses to riboflavin administration. Methods: EGRAC and plasma and erythrocyte concentrations of riboflavin, FMN, and FAD were determined in 124 healthy individuals with a mean age of 69 years. The same measurements were made in a subgroup of 46 individuals with EGRAC 1.20 who participated in a randomized double-blind 12-week intervention study and received riboflavin (1.6 mg/day; n = 23) or placebo (n = 23). Results: Median plasma concentrations were 10.5 nmol/L for riboflavin, 6.6 nmol/L for FMN, and 74 nmol/L for FAD. In erythrocytes, there were only trace amounts of riboflavin, whereas median FMN and FAD concentrations were 44 and 469 nmol/L, respectively. Erythrocyte FMN and FAD correlated with each other and with EGRAC and plasma riboflavin (P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Studies investigating the relationship between plasma total homocysteine (tHcy) and vascular disease usually rely on a single measurement. Little information is available, however, on the seasonal variability of plasma tHcy. The aim of this study was to investigate the seasonal variation in fasting plasma tHcy and related B-vitamin intake and status in a group of people who did not consume fortified foods or take B-vitamin supplements. Methods: In this longitudinal study, a group of 22 healthy people were followed for 1 year. A fasting blood sample and dietary information were collected from each individual every 3 months, i.e., at the end of each season. Results: There was no significant seasonal variation in plasma tHcy or in B-vitamin intake or status with the exception of red cell folate (significantly lower in spring compared with autumn or winter) and serum folate (significantly lower in spring compared with the other seasons). Although the between-person variation in plasma tHcy was high (47%), the within-person variation was low (11%). This low variation, combined with the low methodologic imprecision of 3.8%, yielded a high reliability coefficient for plasma tHcy (0.97). Conclusions: Although there was a small seasonal variation in folate status, there was no corresponding seasonal variation in plasma tHcy. The high reliability coefficient for plasma tHcy suggests that a single measurement is reflective of an individual’s average plasma tHcy concentration, thus indicating its usefulness as a potential predictor of disease. This, however, needs to be confirmed in different subgroups of the population.